Coriolis mass flowmeter factory from China

Top rated coriolis density meter supplier: The accuracy of mass flow meters is one of their key advantages. In contrast to other types of flow meters, they are less affected by changes in temperature and pressure, which can cause errors. This makes them suitable for a variety of applications where accuracy is critical, such as the chemical and pharmaceutical industries. What is a Magnetic Flow Meter? A magnetic flow meter, also known as a magmeter, measures the flow rate of a conductive fluid using magnetic fields. The method works by sending a current through a pair of electrodes, creating a magnetic field. A conductive fluid flows through a pipe, disrupting the magnetic field, and this disturbance is used to determine how fast the fluid flows. Discover more info on coriolis mass flow meter manufacturers.

Comprehensively consider the use requirements and procurement costs of gas turbine flowmeters. When the customized gas turbine flow meter did not appear in the domestic brand, the international brand can be said to be a super profitable product. A medium-sized gas turbine flow requires hundreds of thousands or even hundreds of thousands of yuan. And our domestic brands struggle tenaciously in a harsh environment where the strength and weakness are not an order of magnitude at all. It can be seen that when selecting a gas turbine flow meter, there are many factors to be considered, not only from before the purchase, but also after the purchase of the gas turbine flowmeter, all of which need to be considered. When choosing a gas turbine flowmeter, you must be careful!

Vortex flow meter is the fluid Reynolds number is within a certain range, and its output is only proportional to the volume flow. The output of vortex flowmeter has frequency signal and analog signal, and the analog output is obtained by f/ conversion on the basis of frequency output. This conversion loses about 0.1% accuracy. Therefore, when it is used to measure the steam flow, users prefer to use the frequency output. There are several other reasons why frequency output vortex flowmeters are more popular with users such as thermal companies.

The Insertion Density Meters are equiped with the microprocessors inside, so the sensor could complete the signal conditioning, calculation and diagnosis functions, and it does not need the remote eletronic devices for processing. Typical industries applied include the petrochemical industiry, electricity power industry, wine industry, food industry, pharmaceutical industry, and mineral processing (such as, clay, carbonate, silicate, etc. ) For sepecific applications, the Insertion Density Meters are largely used in the interface detection of the multi-product production lines, density detection of the mixed liquid, end monitoring of the reaction kettle, and the separator interface detection.

Fork density meter can measure the density, concentration, gravity, temperature, and accuracy of liquids without being affected by temperature, pressure, density, and viscosity. Applications of micro motion fork density meter: Pipeline interface inspection, slurry solids monitoring and corrosive acid concentration control; density and concentration monitoring that require rapid response. Continuously measure pipelines in real-time through pipelines and storage tanks to increase installation flexibility and choose from a variety of corrosion-resistant materials to measure the density and concentration of key chemicals. Supports protocols connected to DCS, PLC and flow computers. Pass Hazardous Area Approved Head-Mounted Transmitters extend the range of use, the transmitter supports local configuration and display. Find additional information at https://www.bjssae.com/.

Beijing Sincerity Automatic Equipment Co., Ltd was reformed from the Petrochemical Branch Automatic Equipment Co.,Ltd. Beijing Sincerity is the innovation developed enterprise invested by both the China Petroleum &Chemical Corporation’s Beijing Research Institute of Chemical Industries and the Capital Science and Technology Group. Please be noticed, that all the videos taken are approved by SGS, Switzerland, or TUV, Germany. All the videos are real and without shooting skills or beauty filters.

It has been considered in the design that the steam becomes superheated, or it is difficult to determine which state it is in, or sometimes it is superheated and sometimes saturated, so the temperature and pressure compensation is adopted, and the above phase change has no effect on the measurement results. Considering saturated steam in the design, and adopting pressure compensation, the above-mentioned phase change will bring about a small error, that is, the compensation error caused by the density difference corresponding to the difference between the superheated steam temperature and the saturated steam temperature. The design is based on saturated steam, but temperature compensation is used, that is, the temperature of superheated steam is used as the saturation temperature to check the density table, which will generally cause large errors.